ATV-UTV

DURABATT LITHIUM ION BATTERY SPECIFICATIONS

DURABATT LITHIUM ION BATTERY SELECTION CHART

Battery identifier

Durabatt Lithium

Battery identifier YB10A-A2 YB10L-A2 YB10L-B YB10L-B2 YB12A-A YB12A-B YB12AL-A YB12AL-A2 YB12B-B2 YB12C-A YB14-A2 YB14-B2 YB14A-A1 YB14A-A2 YB14L-A1 YB14L-A2 YB14L-B2 YB16-B-CX YB16B-A YB16C-B YB16C-B YB16CL-B YB16CL-B YB16HL-A-CX YB16HL-A-CX YB16-B YB16-B

Durabatt Lithium

Battery identifier

Durabatt Lithium

Battery identifier

Durabatt Lithium

35-360 35-360 35-324 35-324 35-327 35-335 35-549 35-308 35-308 35-308 35-308 35-321 35-320 35-320 35-321 35-321 35-320 35-573 35-574 35-573 35-549 35-356 35-574 35-335 35-349 35-349 35-349 35-549 35-549 35-306 35-306

35-332 35-324 35-324 35-324 35-327 35-327 35-328 35-328 35-645 35-327 35-332 35-332 35-332 35-332 35-335 35-335 35-335 35-515 35-534 35-515 35-535 35-515 35-534 35-512 35-540 35-512 35-540 35-512 35-540 35-515 35-534

35-512 35-540 35-549 35-356 35-549 35-356 35-349 35-308 35-320 35-308 35-510 35-321 35-320 35-320 35-321 35-321 35-534 35-549 35-356 35-549 35-356 35-503 35-530 35-530 35-518 35-645 35-533 35-516 35-516 35-507 35-306

35-102 35-510 35-508 35-509 35-510 35-509 35-645 35-506 35-332 35-335 35-513 35-513 35-513 35-512 35-515 35-534 35-535 35-535 35-534 35-540 35-540 35-512 35-512 35-540 35-349 35-306 35-510 35-645 35-645 35-645

51814 51913

YB18L-A YB18L-A YB30CL-B YB30CL-B YB30L-B YB30L-B

YTX5L-BS YTX5L-BS YTX7A-BS YTX7A-BS YTX7L-BS YTX9-BS YTX12-BS YTX14-BS

12N10-3A-2

12N10-3B

12N12A-4A-1 12N14-3A 12N24-3 12N5-3B 12N5-4B 12N5.5-3B 12N5.5-4A 12N7-3B 12N7-4A 12N7-4B 12N7D-3B 12N9-3B 12N9-4B-1 GHD14HL-BS GHD30HL-BS GYZ16HL GYZ32HL GYZ32HL GYZ32HL SYB14L-A2 Y50-N18L-A Y50-N18L-A-CX Y50-N18L-A3 Y60-N24AL-B

• (Ultra) High-Power Lithium Iron Phosphate battery technology. • High energy density, with only one third of a lead-acid battery’s weight. • Low self-discharge, it can be used in a vehicle after one year’s storage. • Best low-temperature performance among similar products in the market (UHP cell battery); more suitable for low-temperature environment. • Good vibration resistance, with a silicone rubber covers on the top and a mat at the bottom of the battery container. • More than double times of service life of lead acid battery, estimated life is 5-8 years. • Can be installed in any directions, no need to worry about the leakage. • No corrosive liquid, no toxic heavy metals, environmental friendly. • Cylindrical cell; energy storage welding technology; good safety. • Two-year warranty

YB50-N18L-AT

YB5L-B YB7-A YB7B-B YB7C-A YB7L-B

YTX14AH-BS YTX14AHL-BS

YTX14H

YTX14H-BS YTX16-BS

YB9-B

YB9A-A, YB9L-A2

YTX20

YTX20-BS YTX20-BS YTX20CH

YB9L-B

YHD-12H

YIX30L YIX30L

YTX20CH-BS YTX20H-BS YTX20HL-BS

YIX30L-BS YIX30L-BS

YTX20HL-BS-PW

Main Replacement Lead battery Part #

Cranking Amps*

Voltage (V)

Dimensions (mm±2mm)

Polarity

Approx Weight (kg)

Equal to Lead Battery Capacity**

Battery Cell Type (UHP:Ultra High Power, HP: High Power)

YT7B-BS YT7B-BS YT9B-BS

YTX20L

YTX20L-BS YTX20L-BS YTX24HL

L

W H

35-507 35-306 35-102 35-308 35-510 35-503 35-508 35-320 35-530 35-509 35-324 35-533 35-518 35-327 35-328 35-516 35-645 35-321

YTX4L-BS

45 90 90 90

12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8 12.8

114 114 114 120 114 148 148 134 148 148 134 148 148 134 134 148 148 134

70 70 70 60 70 65 87 75 65 87 88 65 87 75 75 65 87 75

86 86

- + - + - +

0.5 0.6 0.6 0.7 0.6 0.6 0.7 1.0 0.9 0.9 1.1 1.1 1.0 1.1 1.1 1.0 1.0 1.0

3Ah-4Ah 4Ah-6Ah 4Ah-6Ah 4Ah-6Ah 4Ah-8Ah 4Ah-8Ah 4Ah-8Ah 6Ah-10Ah 6Ah-10Ah 6Ah-10Ah 7Ah-12Ah 7Ah-12Ah 7Ah-12Ah 7Ah-12Ah 7Ah-12Ah 8Ah-16Ah 8Ah-16Ah 6Ah-10Ah

UHP

YT12A-BS YT12A-BS YT12B-BS YT12B-BS YT14B-BS YTX4L-BS YTX4L-BS

YTX4L-BS,YTZ5S,YB4L-A,YB4L-B

HP HP HP

YTZ5S YTZ7S

YTX5L-BS

105

12N5-3B,12N5-4B,YB5L-B, 12N5.5-3B, 12N5.5-4A,YB7B-B YTX5L-BS,YTX7L-BS,YTZ7S,YB7C-A

130 Centered Terminals

YB16L-B YB16L-B YB18-A YB18-A

YTZ10S YTZ12S YTZ14S

Y60-N24L-A

125 125 125 150

105

- + + - + - + -

UHP UHP UHP UHP

YB4L-A YB4L-B

YT7B-BS YTX7A-BS

92 94

12N7-4A,12N7-4B,YB7-A,12N9-4B-1, YB9A-A,YB9-B 12N7-3B,12N7D-3B,YB7L-B,12N9-3B, YB9L-A2,YB9L-B

133

150

133

- +

UHP

YT7B-BS,YT9B-BS YTX7A-BS,YTX9-BS

150 150 180 180 180 180 180 250 250

92 94

+ - + - - + + - + - + - - + + - + -

UHP UHP

12N10-3B,12N10-3A-2,YB10L-A2, YB10L-B, YB10L-B2

145

HP

YT12B-BS

130

HP HP HP HP

YTZ10S,YT12A-BS

94

12N12A-4A-1,YB12A-A,YB12A-B,YB12C-A

150 150 130

YB12AL-A,YB12AL-A2 YT12B-BS,YT14B-BS

UHP UHP

YTZ10S,YT12A-BS,YTZ12S,YTX12-BS, YTZ14S,YB12B-B2 YB10A-A2,YTX14AH-BS,YB14-A2, YB14A-A1,YB14A-A2,YB14-B2 YTX14AHL-BS,YB14L-A1,YB14L-A2, YB14L-B2,SYB14L-A2,12N14-3A,

94

Yuasa and Durabatt do not warranty carelessness! There is a set of rules that apply to the to use and care of batteries. If you are a dealer or a mechanic, you know that most people ignore them. A battery is a simple but sophisticated device that needs to be treated accordingly. A new sealed battery is always good unless physically broken. Your technician is soley responsible for its life or death in the first month and the user is responsible for the balance ( you must inspect and recharge at least once a month). You can eliminate almost all claims, that would most likely be refused by following proper procedures. 1 A battery must be prepared within the hour after the seal has been broken. 4 It is essential to fully charge the battery the first time (ex.: a battery charged to only 70% will never again accept more than 70% of it’s capacity). 5 The charging rate must never exceed 1/10 of the batterie’s rated power. Do not overheat! Disrupt charging if battery becomes too hot. Permanent damage can result. 6 Charging time varies from 2 to 18 hours depending on battery and charger, sometimes even more (if in doubt, call us). 7 Readjust level with distilled water if necessary. Charge again for 20 min. to mix electrolyte. Never add acid once charged. 8 Check voltage and specific gravity with professional tools. This will give the exact state of the battery. Call immediately if out of specifications. 9 Get with the times! Get yourself a modern pulse charger (similer to the Battery Tender (08-961) that will charge any type of battery (even maintenance free batteries that require special voltage) automatically and with precision. Show your customers that you are professionals and you give them more for the same price. In the end, this will save you agravation, reputation and time. 2 Only sulphuric acid with a specific gravity of 1,265 must be used (except YT/YTX models supplied with acid). 3 Once filled, the battery must rest for 30 to 60 min., no more, no less. Add acid if level has lowered below full line.

35-332

250

12.8

134

88

165

+ -

1.2

8Ah-16Ah

UHP

35-335

250

12.8

134

88

165

- +

1.2

8Ah-16Ah

UHP

35-506 35-513 35-535 35-360 35-515 35-512

YTX14-BS

250 270 375 375 375 375

12.8 12.8 12.8 12.8 12.8 12.8

148 148 148 185 175 175

87 87 87 80 87 87

145 145 145 170 155 155

+ - + - + - - + + - - +

1.2 1.5 1.7 1.9 1.7 1.7

8Ah-16Ah 12Ah-18Ah 16Ah-24Ah 16Ah-24Ah 16Ah-24Ah 16Ah-24Ah

UHP

YTX14H,YTX14H-BS, YTX16-BS YB16B-A,YTX20CH,YTX20CH-BS

HP

UHP UHP UHP UHP

51814, 51913

YB16-B,YB16C-B,YB16-B-CX,YB18-A,YTX20-BS,

YB16L-B,YB16CL-B,YB16HL-A-CX, YB18L-A,YTX20,YTX20L,YTX20L-BS YB16-B,YB16C-B,YB18-A,YTX20-BS, YTX20H-BS, YHD-12H

35-534

500

12.8

175

87

155

+ -

2.1

20Ah-30Ah

UHP

35-540

YB16L-B,YB16CL-B,YB16HL-A-CX, YB18L-A, YTX20L-BS,YTX20HL-BS, YTX20HL-BS-PW Y50-N18L-A,YB50-N18L-AT,Y50-N18L-A-CX, Y50-N18L-A3,YTX24HL,53030 YIX30L,YIX30L-BS,YB30L-B,YB30CL-B, GYZ32HL, Y60-N24AL-B, Y60-N24L-A, 12N24-3 YIX30L,YIX30L-BS,YB30L-B,YB30CL-B, GYZ32HL

500

12.8

175

87

155

- +

2.1

20Ah-30Ah

UHP

35-349

500

12.8

175

87

155

- +

2.1

20Ah-30Ah

UHP

35-549

625

12.8

166

124

175

- +

2.6

30Ah-40Ah

UHP

35-356 35-573 35-574

1250

12.8 12.8 12.8

166 149 166

124

175 144 175

- + - + - +

4.1 1.2 2.6

30Ah-70Ah 14Ah-16Ah 30Ah-40Ah

UHP UHP UHP

GHD14HL-BS,GYZ16HL GHD30HL-BS,GYZ32HL

250 625

87

130

*Cranking Amps is measured by real discharging(10sec@25°C), please don’t use lead battery CA tester to measure the lithium battery CA value. **Operation temperature: -10°C ~ 55°C (14°F ~ 131°F), If the ambient temperature is lower than 15°C, the PbEq should be smaller.

Made with FlippingBook Digital Publishing Software